Dew Point Calculator

This dew point calculator finds the temperature at which water condenses, from your air temperature and humidity. Add your coldest surface to see how close it is to getting wet.

Temperature
Find
°C

%

°C

Leaves at lights-off, an outside wall, a window or ducting. Not sure? Use your night-time air temperature.

Lights-off
°C

The same water stays in the air, so humidity rises as the room cools.

Dew point

—

—

Mould risk from humidity
—
Max RH before that surface condenses
—
Absolute humidity
—
Vapour pressure
—
Humidity at lights-off
—

What to do

Next: Size a dehumidifier to bring the humidity down

Dew point in a grow room

Want every value at once? The dew point chart lists the dew point for each temperature and humidity, ready to print.

The dew point is the temperature at which the air’s water vapour starts turning into liquid. It depends only on how much water is in the air, so it does not change when the room warms or cools; relative humidity does.

That is why condensation appears at lights-off: the room and leaves cool towards a dew point that has not moved.

Formula (Magnus, same constants as Tetens)
γ  = ln(RH/100) + 17.27·T / (T + 237.3)
Td = 237.3·γ / (17.27 − γ)

What a dew point calculator tells a grower

The dew point is the temperature at which the water already in the air starts to turn into liquid. Any leaf, wall, window or duct at or below it gets wet, and wet surfaces are where mould and leaf diseases start. Botrytis, the grey mould behind bud rot, thrives at 85% humidity and above.

The calculator compares the dew point with your coldest surface. Within 2 °C (3.6 °F) of the dew point counts as high risk, and within 4 °C (7.2 °F) as moderate. No published margin exists for this, so these are our rules of thumb, with room for sensor error and for surfaces colder than you measured. It also rates mould risk from humidity alone: moderate from 70%, high from 85%. Alongside the dew point you get absolute humidity in g/m³ and vapour pressure in kPa, the actual amount of water in the air.

Dew point formula, with real numbers

The calculator uses the Magnus form with the same constants as the vapour pressure formula on the rest of the site. Take a room at 24 °C (75.2 °F) and 65% RH:

  • γ = ln(0.65) + 17.27 × 24 ÷ (24 + 237.3) = 1.1554
  • Dew point = 237.3 × 1.1554 ÷ (17.27 − 1.1554) = 17.0 °C (62.6 °F)

If the coldest surface is a wall at 18 °C (64.4 °F), it sits only 1.0 °C (1.8 °F) above the dew point: high risk. The result shows that the wall starts to condense once humidity passes about 69%, and the advice is to bring humidity below about 57% to keep a 3 °C (5 °F) margin.

It also works the other way round. As a humidity dew point calculator, choose Find: Humidity, enter 25 °C (77 °F) and a 15 °C (59 °F) dew point, and it returns about 54% RH. Choose Temperature to find the air temperature instead.

Lights-off humidity: where condensation starts

Most dew point tools stop at one reading. In a grow room the risky moment is lights-off. The water in the air stays the same, so the dew point does not move, but the room cools towards it and humidity climbs.

Enter the lights-off temperature under Lights-off. In the room above, cooling from 24 °C to 19 °C (66.2 °F) lifts humidity to about 88%, high for mould, and leaves at 19 °C sit less than 2 °C above the dew point. Start the same room at 55% RH instead and the night reading is about 75%, with a margin of 4.6 °C (8.3 °F).

  • Lower humidity before the lights go off, not after.
  • Keep the night temperature closer to the day temperature.
  • Keep air moving over the canopy and cold walls.
  • Run the dehumidifier or exhaust fan into the dark period. The dehumidifier size calculator and the exhaust fan calculator help you size equipment that can keep up.

Common dew point mistakes

  • Only measuring the air. Condensation forms on the coldest surface, not in the middle of the room. Measure an outside wall, a window or the top leaves at lights-off.
  • Watching humidity instead of the dew point. Humidity changes every time the room warms or cools. The dew point only changes when water is added or removed.
  • A hygrometer next to the light or the humidifier. It reads that spot, not the room.
  • Converting wet and dry bulb readings by hand. The dry bulb and wet bulb calculator turns them into humidity and dew point.

Want every value at once, to pin on the wall? The printable dew point chart lists the dew point for each temperature and humidity.

FAQ

Questions growers ask

How do I calculate dew point?

Use the Magnus formula: γ = ln(RH/100) + 17.27·T/(T + 237.3), then dew point = 237.3·γ/(17.27 − γ), with T in °C. At 24 °C and 65% RH, γ is 1.1554 and the dew point is 17.0 °C (62.6 °F). The calculator does this for you and shows the result as you type.

How do I measure dew point?

Measure air temperature and relative humidity with a hygrometer, then enter both here. Some hygrometers show the dew point directly; enter that with Find: Humidity to check the humidity it implies. With a psychrometer, enter the dry and wet bulb readings in the wet bulb calculator, which also gives the dew point.

What is the dew point rule?

Keep every surface a few degrees above the dew point. There is no single published grow room margin. This calculator rates a surface within 2 °C (3.6 °F) of the dew point as high risk and within 4 °C (7.2 °F) as moderate, and its advice aims for a 3 °C (5 °F) margin.

What does a dew point of 70 mean?

A 70 °F (21.1 °C) dew point means a lot of water in the air: anything at or below 70 °F gets wet. Outdoors, the US National Weather Service calls 65 °F and above oppressive. In a grow room at 80 °F, a 70 °F dew point means about 72% humidity.

What does a 20 degree dew point mean?

It depends on the unit. A 20 °F (−6.7 °C) dew point is very dry air: heated to 70 °F indoors, it is only about 15% humidity. A 20 °C (68 °F) dew point is humid, in the National Weather Service's oppressive band. In a 26 °C grow room it means about 70% humidity.

Why does humidity rise at lights-off?

Cooler air holds less water, but the water already in the air stays. Relative humidity is the share of what the air could hold, so it climbs as the room cools. Air at 26 °C and 60% RH cooled to 21 °C reaches about 81% RH, though the dew point stays at 17.6 °C.

How do I stop condensation in a grow tent?

Keep the coldest surface, usually the leaves at lights-off, more than 4 °C (7.2 °F) above the dew point, which this calculator rates low risk. Lower humidity before the lights go off, keep the night temperature up, keep air moving, and run the dehumidifier or exhaust fan into the dark period.

What is a safe dew point margin in a grow room?

Keep the coldest surface — leaves at lights-off, walls, windows, ducting — at least 2–3 °C (4–5 °F) above the dew point. Closer than that and small temperature swings cause condensation.

Sources

The formulas and target ranges on this page come from these references.

  1. University of Arizona, AZMet: dew point from temperature and relative humidity. azmet.arizona.edu/azmet/dewpoint.html
  2. Allen, Pereira, Raes & Smith (1998). Crop evapotranspiration, FAO Irrigation and Drainage Paper 56, chapter 3, equations 11 and 19. www.fao.org/4/x0490e/x0490e07.htm
  3. University of Kentucky, Center for Crop Diversification CCD-CP-63: Hydroponic lettuce. ccd.uky.edu/sites/default/files/2026-02/ccd-cp-63_hydrolettuce-updated_accessible.pdf
  4. US EPA: A brief guide to mold, moisture and your home (keep indoor humidity below 60%). www.epa.gov/mold/brief-guide-mold-moisture-and-your-home
  5. Glass et al. (2017), ASTM STP1599, on ASHRAE Standard 160: surface relative humidity below 80% (30-day average) to avoid mould. research.fs.usda.gov/treesearch/55524