Skip to content
VPD Calculator

How to Read a VPD Chart (With Examples)

By 7 min read

A VPD chart looks like a wall of coloured numbers, and the first time you see one it is hard to know where to start. The good news is that every VPD chart works the same way: two readings in, one number and one colour out. Once you know the four steps, reading one takes about ten seconds.

This guide walks through those steps with real examples, then covers the part most guides skip: why two VPD charts can give different answers for the same grow room, and which one to believe.

If you are new to VPD itself, start with What Is VPD? A Simple Guide for Growers. In short, VPD (vapour pressure deficit) measures how hard the air pulls water out of your leaves.

What a VPD chart shows

A VPD chart is a lookup table. Somebody has already done the maths for every common combination of temperature and humidity, so you do not have to.

  • Each row is an air temperature. On our VPD chart, the Celsius sheet runs from 16 to 34 °C and the Fahrenheit sheet from 60 to 94 °F.
  • Each column is a relative humidity, from 30% to 95%.
  • Each cell is the VPD for that temperature and humidity, in kPa.
  • The colour of the cell tells you whether that VPD suits the growth stage the chart is set for: blue when the air is too humid, green when it is in range, orange and red when it is too dry.

Because the colours depend on the growth stage, a good chart lets you pick the stage. The same cell can be green for flowering and orange for seedlings.

Reading a VPD chart in four steps

Step 1: pick the right chart

Before you look up anything, check three things at the top of the chart:

  1. Your temperature unit. Use the °C sheet if your thermometer reads Celsius, the °F sheet if it reads Fahrenheit.
  2. Your growth stage. Seedlings and clones, veg, early flower or late flower.
  3. Air or leaf VPD. A leaf VPD chart assumes your leaves are a little cooler than the air. Ours sets the leaf 2 °C (3.6 °F) cooler by default, which suits LED lights, and you can change it.

Step 2: find your temperature row

Read the temperature at canopy height, then find that row. If your reading falls between two rows, use the nearer one; the difference between neighbouring rows is small.

Step 3: find your humidity column

Read the humidity at the same spot and find that column.

Step 4: read the cell

Where the row and column meet is your VPD. Look at the number, then at the colour. Green means leave it alone. Any other colour means change one thing and check again later.

Worked examples

All of these use a leaf VPD chart with the leaf 2 °C (3.6 °F) cooler than the air, the LED setting.

Example 1: a tent in veg. It reads 26 °C and 60% humidity. Find the 26 °C row and the 60% column: the cell reads 0.97 kPa. The veg range is 0.8–1.2 kPa, so it is green. Nothing to do.

Example 2: the same tent in Fahrenheit. 78 °F and 60% reads 0.94 kPa, also green for veg. The two sheets agree to within a few hundredths, because 78 °F is a fraction cooler than 26 °C.

Example 3: a humid tent. 24 °C and 70% reads 0.56 kPa. That is below the veg range, so the cell is blue: the air is too damp. You would lower the humidity a little, or let the temperature rise a degree or two.

Example 4: a hot, dry tent. 29 °C and 45% reads 1.76 kPa. That is above every stage’s range, so the cell is red. Leaves here lose water faster than the roots can supply it. You would raise the humidity, cool the room, or both.

Which way to move on the chart

Once you know where you are, the chart also shows how to get to green:

You want to Move on the chart
Lower VPD Right (more humidity) or up (cooler)
Raise VPD Left (less humidity) or down (warmer)

Pick whichever is easier to change in your room. Humidity is usually the easier lever in a tent; temperature is often easier in a large room with air conditioning. Change one thing by a small step, wait half an hour for the room to settle, and read the chart again.

Why two VPD charts can disagree

If you have compared a few charts online, you have probably noticed that they do not always agree. At 26 °C and 60%, one chart might say 1.34 kPa and another 0.97 kPa. Neither is broken. There are four usual reasons.

Air VPD vs leaf VPD

An air VPD chart assumes the leaf is exactly as warm as the air. At 26 °C and 60%, that gives 1.34 kPa. A leaf VPD chart with leaves 2 °C cooler gives 0.97 kPa for the same room. The formula is the same standard one from the FAO’s crop water guide (FAO-56); only the leaf temperature differs.

Leaves are rarely at exactly air temperature. Nelson and Bugbee (2015) compared leaves in sunlight, in a greenhouse, and under HPS and LED lamps. Leaves that were not short of water were typically within 2 °C of the air, and their model puts leaves about 1.3 °C cooler under LEDs than under HPS. They also found that water stress matters more than the type of light: thirsty leaves can run well above air temperature. That is why a leaf chart is more useful indoors, as long as its offset matches your plants, and why measuring a leaf beats guessing.

The leaf offset

Even two leaf VPD charts can differ if they use different offsets. At 26 °C and 60%, a 2 °C offset (typical under LEDs) gives 0.97 kPa, while a 0.7 °C offset (typical under HPS) gives 1.21 kPa. If your chart lets you set the offset, set it for your lights, or measure a leaf with an infrared thermometer and use the leaf VPD calculator.

The target ranges

Charts colour their cells from different target ranges. Ours uses 0.5–1.0 kPa for seedlings, 0.8–1.2 for veg, 1.0–1.5 for early flower and 1.2–1.5 for late flower. They are based on the cannabis ranges reported by Corredor-Perilla and colleagues (2025), which start veg at 0.7 and do not split flower. A chart built for tomatoes or a general greenhouse will colour the same numbers differently.

The units

Most charts use kPa, but some use millibars (mbar) or pounds per square inch (psi). 1 kPa is 10 mbar or about 0.145 psi, using the standard conversion factors in NIST Handbook 44. A reading of 10 on a millibar chart is the same as 1.0 kPa.

Mistakes that make a chart misleading

  • Measuring in the wrong place. A sensor next to the light, the fan or the floor reads a different climate from the canopy. Hang it at leaf height, shaded from the light.
  • Only reading it in the day. When the lights go off, the temperature drops and the humidity climbs. A tent at 26 °C and 55% by day (1.14 kPa at the leaf) holds about 70% at 22 °C at night, with no change in the water in the air. Read the chart for the night too.
  • Trusting a cheap hygrometer blindly. If your humidity reads 5% out, at 26 °C your VPD is about 0.17 kPa out, close to half a band. Check two sensors side by side now and then.
  • Using an air VPD chart under LEDs. As the example above shows, it can read a full stage drier than your leaves feel.

Quick answers

What is the best VPD chart to use? One that shows leaf VPD, lets you set the leaf offset for your lights, and lets you pick your growth stage. Our VPD chart does all three, in °C and °F, and prints to A4 or US Letter.

Do I read temperature or humidity first? It does not matter. You need the cell where your temperature row meets your humidity column.

What if my reading is between two rows? Use the nearer row. For an exact figure, type your readings into the VPD calculator instead.

Why does the chart turn blue at high humidity? Blue means the VPD is too low for the stage: the air is so humid that leaves can barely give off water, which slows growth and raises the risk of mould.

To try it with your own numbers, open the VPD chart, set your stage and lights, and find your row and column.

Sources

The formulas and target ranges on this page come from these references.

  1. Allen, Pereira, Raes & Smith (1998). Crop evapotranspiration, FAO Irrigation and Drainage Paper 56, chapter 3, equations 11 and 19. www.fao.org/4/x0490e/x0490e07.htm
  2. Corredor-Perilla, Kwon & Park (2025). Elevated relative humidity significantly decreases cannabinoid concentrations while delaying flowering development in Cannabis. Frontiers in Plant Science (leaf VPD equation 3, and the cannabis VPD ranges it reports from earlier work). doi.org/10.3389/fpls.2025.1678142
  3. Nelson & Bugbee (2015). Analysis of environmental effects on leaf temperature under sunlight, high pressure sodium and light emitting diodes. PLoS ONE 10(10), e0138930. doi.org/10.1371/journal.pone.0138930
  4. NIST Handbook 44 (2026), Appendix C: units and conversion factors. www.nist.gov/document/2026-nist-handbook-44-appendix-c