What Is VPD? A Simple Guide for Growers

By 8 min read

If you grow indoors, sooner or later someone tells you to “check your VPD”. It sounds technical, but the idea is simple: VPD tells you how hard the air is pulling water out of your plants. Get it right and plants drink, feed and grow steadily. Get it wrong and they either sit in damp air inviting mould, or close up and stall in air that is too dry.

This guide explains what VPD means, how it is worked out, which numbers to aim for at each growth stage, and what to change when your reading is off.

VPD in one sentence

VPD stands for vapour pressure deficit. It is the gap between how much water vapour the air could hold at its temperature and how much it does hold right now. The University of Arizona’s extension service puts it as the difference between the moisture the air can hold when fully saturated and the moisture actually present, and calls it a measure of “the atmosphere’s demand for water”.

VPD is measured in kilopascals (kPa), a unit of pressure. Typical grow-room readings sit between about 0.4 and 1.6 kPa:

  • Low VPD (under about 0.5 kPa): the air is almost full of water. Leaves give off little moisture, and wet surfaces stay wet.
  • High VPD (over about 1.5 kPa): the air is thirsty. Leaves lose water fast, and the plant may close its pores (stomata) to protect itself.

Why growers use VPD instead of humidity alone

Relative humidity (RH) only tells you how full the air is as a percentage of what it could hold at that temperature. Warm air can hold far more water than cool air, so the same RH means very different things at different temperatures.

Take 60% RH in two rooms:

Room Temperature Humidity Air VPD
Cool tent 20 °C (68 °F) 60% 0.94 kPa
Warm tent 30 °C (86 °F) 60% 1.70 kPa

Same humidity, but the warm tent pulls water from leaves almost twice as hard. That is why a humidity number on its own can mislead you, and why VPD, which combines temperature and humidity, is a better guide to how your plants actually feel. The Arizona extension handout makes the same point: because VPD includes both, it “often provides a better indication of crop water demand than either variable alone”.

How VPD is worked out

You do not need to do this by hand (our VPD calculator does it instantly), but seeing the steps once makes the number much less mysterious. The method below is the standard one from the FAO’s crop water guide (FAO-56).

Step 1: how much water the air could hold. This is the saturation vapour pressure (SVP), and it depends only on temperature:

SVP = 0.61078 × e^(17.27 × T ÷ (T + 237.3)), with T in °C and the answer in kPa.

Step 2: how much water it actually holds. Multiply SVP by the relative humidity as a fraction: actual vapour pressure = SVP × RH ÷ 100.

Step 3: the gap between them. Air VPD = SVP − actual vapour pressure.

A worked example

Your tent reads 25 °C (77 °F) and 60% RH.

  1. SVP at 25 °C = 3.17 kPa.
  2. Actual vapour pressure = 3.17 × 0.60 = 1.90 kPa.
  3. Air VPD = 3.17 − 1.90 = 1.27 kPa.

That is a comfortable number for flowering plants, and on the dry side for veg.

Air VPD vs leaf VPD

The example above is air VPD: it assumes the leaf is the same temperature as the air. Often it is not. Leaves cool themselves as water evaporates from them, while light and dry roots warm them. Nelson and Bugbee (2015) compared leaves in sunlight, in a greenhouse, and under HPS and LED lamps. Leaves that were not short of water were typically within 2 °C of the air, and their model puts leaves about 1.3 °C cooler under LEDs than under HPS. They also found that water stress matters more than the type of light: thirsty leaves can run well above air temperature.

Leaf VPD uses the leaf’s own temperature for the “could hold” part, because the air right inside the leaf is saturated at leaf temperature:

Leaf VPD = SVP(leaf temperature) − actual vapour pressure of the air.

Back to our tent at 25 °C and 60% RH, with leaves 2 °C cooler, at 23 °C:

  1. SVP at 23 °C = 2.81 kPa.
  2. Actual vapour pressure of the air is still 1.90 kPa.
  3. Leaf VPD = 2.81 − 1.90 = 0.91 kPa.

That is a big difference: 1.27 kPa of air VPD becomes 0.91 kPa at the leaf, which moves the room from “flower” to “veg” conditions. If you grow under LEDs, leaf VPD is the number to trust. You can measure leaf temperature with an infrared thermometer pointed at a leaf in the canopy, or use a typical offset. Our leaf VPD calculator handles both.

What VPD does to your plants

  • Too low: little water leaves the leaf, so the flow of nutrients from the roots slows, and leaves stay wet for longer. You may see slow growth, droopy or soft leaves, mould and mildew, and bud rot in flower.
  • In range: steady transpiration pulls water and nutrients up from the roots. Leaves are firm and upright, and growth is even.
  • Too high: leaves lose water faster than the roots can replace it, and the plant partly closes its stomata. You may see leaf edges curling up, crispy tips, slower growth, and plants that look thirsty even when watered.

The Arizona handout describes the same two failure modes: high VPD leads to plants “partially closing their stomata”, which limits photosynthesis, while low VPD reduces nutrient movement and is linked with longer leaf wetness that favours fungal and bacterial disease.

Good VPD for each growth stage

Young plants have small root systems, so they want gentle, humid air. As they grow, they can handle, and benefit from, drier air. Late in flower, dense buds need the driest air of the cycle to stay free of mould. These are the leaf VPD targets our calculators use. They are based on the cannabis VPD ranges that Corredor-Perilla and colleagues (2025) report from earlier work: 0.5–1.0 kPa for clones and seedlings, 0.7–1.2 in veg and 1.0–1.5 in flower. We start veg a little higher and split flower in two, so late flower gets the drier half. Treat them as starting points:

Stage Leaf VPD Humidity at 25 °C (77 °F), leaves 2 °C cooler
Seedlings and clones 0.5–1.0 kPa about 57–73%
Vegetative 0.8–1.2 kPa about 51–63%
Early flower 1.0–1.5 kPa about 41–57%
Late flower 1.2–1.5 kPa about 41–51%

The humidity column changes with temperature, so treat it as an example, not a rule. For your own temperature, look it up on the VPD chart, which has the whole grid in °C and °F.

A note on autoflowers: they move from seedling to flower without a light change, so most growers simply follow the same ranges by stage, moving to the flower ranges once the first pistils appear.

How to change your VPD

VPD has only two levers: temperature and humidity. To make it go the way you want:

To lower VPD (air too dry):

  • Raise humidity: a humidifier, a wet towel or open tray of water in a small tent, or more plants in the space.
  • Lower the temperature a little, if the room is running hot.
  • Slow the exhaust fan so less moist air is pulled out.

To raise VPD (air too damp):

  • Lower humidity: a dehumidifier, more air exchange, or fewer wet surfaces (cover reservoirs, avoid overwatering).
  • Raise the temperature slightly, if the room is cool.
  • Improve air movement inside the canopy, so pockets of damp air do not sit around the leaves.

Change one thing at a time and give the room half an hour to settle before you read it again.

Mistakes that throw VPD off

  • Forgetting lights-off. When the lights go off, the temperature drops, and the same amount of water in the air becomes a much higher humidity. Air that held 60% at 25 °C is about 76% at 21 °C, and its VPD falls from 1.27 to about 0.59 kPa. This night-time humidity spike is a common cause of mould. Check your readings at night, not just in the day.
  • A sensor in the wrong place. A hygrometer next to the light, the fan or the floor reads a different climate from the one your plants live in. Put it at canopy height, in the shade of a leaf.
  • Chasing a perfect number. VPD ranges are a guide, not a target to hit to two decimal places. A room that stays inside the range steadily beats one that swings back and forth while you fiddle with settings.
  • Mixing up air and leaf VPD. Charts and calculators do not always say which one they show. Under LEDs, the difference can be a whole growth stage, as the worked example above shows.

Quick answers

Is VPD the same as humidity? No. Humidity is one of the two things VPD is made from; the other is temperature. The same humidity can give a low or a high VPD depending on how warm the room is.

What is a good VPD? For most indoor plants, a leaf VPD around 0.8–1.2 kPa in veg and 1.0–1.5 kPa in flower. Seedlings and clones prefer 0.5–1.0 kPa.

Is high VPD bad? Only when it is too high for the stage. Even in late flower the range tops out at 1.5 kPa; well above that, plants lose water faster than their roots can replace it and start to close their stomata.

Do I need a special meter? No. Any reasonably accurate thermometer and hygrometer will do; a calculator turns the two readings into VPD. An infrared thermometer for leaf temperature is a useful extra.

Put your own readings into the VPD calculator to see where your room sits, and exactly what humidity or temperature to set for your stage.

Sources

The formulas and target ranges on this page come from these references.

  1. Allen, Pereira, Raes & Smith (1998). Crop evapotranspiration, FAO Irrigation and Drainage Paper 56, chapter 3, equations 11 and 19. www.fao.org/4/x0490e/x0490e07.htm
  2. Mohammed (2026). What the air is telling you: understanding vapor pressure deficit and why it matters in Yuma agriculture. University of Arizona Cooperative Extension handout. extension.arizona.edu/publication/what-air-telling-you-understanding-vapor-pressure-deficit-and-why-it-matters-yuma
  3. Corredor-Perilla, Kwon & Park (2025). Elevated relative humidity significantly decreases cannabinoid concentrations while delaying flowering development in Cannabis. Frontiers in Plant Science (leaf VPD equation 3, and the cannabis VPD ranges it reports from earlier work). doi.org/10.3389/fpls.2025.1678142
  4. Nelson & Bugbee (2015). Analysis of environmental effects on leaf temperature under sunlight, high pressure sodium and light emitting diodes. PLoS ONE 10(10), e0138930. doi.org/10.1371/journal.pone.0138930