Skip to content
VPD Calculator

Best VPD for Each Stage: Seedlings, Veg and Flower

By 6 min read

There is no single “best VPD”. A seedling with a root system the size of your thumb wants very different air from a plant in its last weeks of flower. What works is a range for each stage, and a plan for moving from one range to the next as the plant grows.

This guide gives the VPD range for each growth stage, explains why each one is set where it is, and turns every range into the humidity to set at common grow-room temperatures, in °C and °F.

All the numbers are leaf VPD with the leaf 2 °C (3.6 °F) cooler than the air, which is typical under LED lights. If VPD is new to you, read What Is VPD? first.

The ranges at a glance

Stage Leaf VPD
Seedlings and clones 0.5–1.0 kPa
Vegetative 0.8–1.2 kPa
Early flower 1.0–1.5 kPa
Late flower 1.2–1.5 kPa

These are the leaf VPD targets our VPD calculator and VPD chart use. They are based on the cannabis VPD ranges Corredor-Perilla, Kwon and Park (2025) report from earlier work: 0.5–1.0 kPa for clones and seedlings, 0.7–1.2 in veg and 1.0–1.5 in flower. We start veg a little higher and split flower in two. The pattern is simple: VPD rises as the plant matures. Young plants get gentle, humid air; mature flowering plants get the driest air of the cycle.

Seedlings and clones: 0.5–1.0 kPa

Seedlings have tiny roots, and unrooted clones have none at all. They cannot pull up much water, so if the air draws water out of the leaves faster than the roots can replace it, they wilt. Low VPD keeps transpiration gentle while the roots develop. That is why clones go under a humidity dome.

Humidity to aim for:

Air temperature Humidity for 0.5–1.0 kPa
22 °C (72 °F) 51–70%
24 °C (75 °F) 55–72%
26 °C (79 °F) 59–74%
28 °C (82 °F) 62–76%

Watch for: leaves that droop by the end of the light period (VPD too high for the roots), or damp soil surfaces that never dry and grow algae or fungus gnats (VPD too low for too long).

Vegetative stage: 0.8–1.2 kPa

Once roots are established, the plant can move more water, and it should. Transpiration is the pump that pulls water and dissolved nutrients up from the roots, so a steady flow of water through the leaves supports fast leaf and stem growth.

Air temperature Humidity for 0.8–1.2 kPa
22 °C (72 °F) 43–58%
24 °C (75 °F) 48–62%
26 °C (79 °F) 53–65%
28 °C (82 °F) 57–68%

Watch for: soft, floppy growth and slow drying of the medium (VPD too low), or leaf edges curling up and crispy tips (too high).

Early flower: 1.0–1.5 kPa

When flowering starts, it is time to dry the air a little. Early buds are forming, and from here on, damp air is the main risk. The range widens to 1.0–1.5 kPa, so you have more room to work with.

Air temperature Humidity for 1.0–1.5 kPa
22 °C (72 °F) 32–51%
24 °C (75 °F) 38–55%
26 °C (79 °F) 44–59%
28 °C (82 °F) 49–62%

Late flower: 1.2–1.5 kPa

In the last weeks, buds are at their densest, and dense buds hold moisture inside. That is where bud rot (grey mould) starts. Late flower has the narrowest and driest range: 1.2–1.5 kPa.

Air temperature Humidity for 1.2–1.5 kPa
22 °C (72 °F) 32–43%
24 °C (75 °F) 38–48%
26 °C (79 °F) 44–53%
28 °C (82 °F) 49–57%

Keeping the air drier in flower is about more than mould. Corredor-Perilla and colleagues grew one CBD-dominant strain in very humid air (78–98%) and in drier air (37–58%). The humid plants made far less flower, had lower cannabinoid concentrations and flowered later. That is one strain at an extreme humidity, so it does not prove that a slightly damp room does the same, but it shows the direction.

None of the cannabis ranges that paper reports goes above 1.5 kPa, so neither do ours. Much above that, plants lose water faster than they can take it up; the University of Arizona’s extension handout on VPD describes plants partially closing their stomata under high VPD, which limits photosynthesis.

The best VPD for flowering with added CO₂

If you add CO₂ to the room, the target moves up a little. Hydrobuilder’s VPD guide suggests adjusting towards the higher end of each range under elevated CO₂ (roughly 1,200 ppm or more). For early flower, that means aiming for about 1.25–1.5 kPa rather than the bottom of the band.

How to move from one stage to the next

Do not jump from the middle of the veg range to the middle of the late-flower range overnight. A sudden change in VPD is a sudden change in how fast the plant loses water.

  • Change the humidity a few percent at a time, over several days, as the plant moves into the next stage.
  • Change one thing at a time. If you lower the humidity, leave the temperature alone until the room has settled.
  • Use the overlap. The veg and early-flower ranges overlap between 1.0 and 1.2 kPa. Sitting at about 1.1 kPa for the first week of flower is a gentle way to switch.

Do not forget lights-off

All the tables above are for the lights-on period. When the lights go off, the room cools and the humidity climbs, even though there is no more water in the air.

Take a tent at 26 °C and 55% by day, a leaf VPD of 1.14 kPa: perfect for veg or early flower. If it cools to 22 °C at night, the same air reads about 70% humidity. With the lights off, leaves are no longer warmed by the lamps and sit close to the air temperature, so the VPD at night is about 0.80 kPa. That is fine in veg, but low for flower, and it is the reason many growers see mould appear at night.

If your night humidity climbs into the seedling range during flower, run a dehumidifier at night, or keep the temperature drop smaller. Our dehumidifier calculator works out the size you need.

A note on leaf temperature

Every table here assumes the leaf is 2 °C cooler than the air, which suits LED lights. Under HPS lamps leaves run a little warmer, so the same room gives a higher leaf VPD. Nelson and Bugbee (2015) compared leaves in sunlight, in a greenhouse, and under HPS and LED lamps. Leaves that were not short of water were typically within 2 °C of the air, and their model puts leaves about 1.3 °C cooler under LEDs than under HPS. They also found that water stress matters more than the type of light: thirsty leaves can run well above air temperature. If you grow under HPS, or you have measured your leaves with an infrared thermometer, set your own offset in the VPD calculator and it will work out the humidity for you.

Quick answers

What is the best VPD for flowering? 1.0–1.5 kPa in early flower and 1.2–1.5 kPa in late flower. At 26 °C (79 °F) with LED lights, that is about 44–59% humidity in early flower and 44–53% in late flower.

What is the best VPD for veg? 0.8–1.2 kPa. At 24 °C (75 °F), that is about 48–62% humidity.

What VPD for seedlings? 0.5–1.0 kPa, which needs high humidity: about 55–72% at 24 °C (75 °F).

Is 1.6 VPD too high? For every stage, yes. Even late flower tops out at 1.5 kPa.

Should VPD be the same day and night? It cannot be exactly, because the temperature changes, but try to keep the night VPD from dropping far below the stage’s range.

For your exact numbers, type your temperature and humidity into the VPD calculator and choose your stage; it tells you what to set.

Sources

The formulas and target ranges on this page come from these references.

  1. Corredor-Perilla, Kwon & Park (2025). Elevated relative humidity significantly decreases cannabinoid concentrations while delaying flowering development in Cannabis. Frontiers in Plant Science (leaf VPD equation 3, and the cannabis VPD ranges it reports from earlier work). doi.org/10.3389/fpls.2025.1678142
  2. Allen, Pereira, Raes & Smith (1998). Crop evapotranspiration, FAO Irrigation and Drainage Paper 56, chapter 3, equations 11 and 19. www.fao.org/4/x0490e/x0490e07.htm
  3. Mohammed (2026). What the air is telling you: understanding vapor pressure deficit and why it matters in Yuma agriculture. University of Arizona Cooperative Extension handout. extension.arizona.edu/publication/what-air-telling-you-understanding-vapor-pressure-deficit-and-why-it-matters-yuma
  4. Hydrobuilder Learning Center. Vapor pressure deficit (VPD): “adjust toward the higher end of each range under elevated CO2 (roughly 1,200+ ppm)”. learn.hydrobuilder.com/vapor-pressure-deficit-vpd/
  5. Nelson & Bugbee (2015). Analysis of environmental effects on leaf temperature under sunlight, high pressure sodium and light emitting diodes. PLoS ONE 10(10), e0138930. doi.org/10.1371/journal.pone.0138930